Keep the shape of a bay and the edge above brickwork in the repair specification.

For render repairs in Sutton in Ashfield, show where the damaged area ends as well as where it begins. A patch on roughcast may meet a curved bay, a projecting lintel or an exposed brick base. The repair needs an agreed profile and junction, not just a matching colour. Phone 01623 579297 with the affected elevation, approximate height and any earlier repair details available, then agree what needs inspecting before the work can be priced.
Measure the curved face rather than a flat rectangle
The March 2015 Church and Market Place appraisal describes Kirkside on Hack Lane as roughcast-rendered above a brick plinth. It also records a curved ground-floor bay and tile-crease lintels at the windows and doors. This named building provides a local example of a textured finish meeting shaped features.
Where your own repair wraps around a bay, mark the front, curved portion and return individually. Show the relationship with the sill and any overhang. The person pricing the work needs to know whether one damaged face is being repaired or the whole feature is being refinished. Check that the proposed preparation can reach the edge without damaging the retained brick, roof covering or joinery beside it.
Scroll sideways to see the full table. Keyboard: focus the table, then use the arrow keys.
| Part | Detail to show |
|---|---|
| Curved wall | Length around the curve and affected height |
| Sill corner | Crack position and any previous patch |
| Lintel or head | Profile and retained exposed material |
| Base | Render edge, brickwork and adjoining path |
| Side return | Room to prepare and finish the surface |
Retain the intended edge above the plinth
At the bottom of the wall, photograph the finish, exposed masonry and adjoining ground together. Note any path resurfacing or change of level since the render was installed. The survey should establish the existing damp-proofing and drainage arrangements before a new edge is selected. A convenient straight line on the wall is not enough to decide where the repair should finish.
Ask whether the visible damage is confined to the surface or whether opening-up is needed around a bead, joint or retained edge. Include what happens if the material behind the patch differs from the expected construction. Keep a proposed change to ground level separate from the render scope so each alteration is assessed and the meeting point is deliberately detailed.

Choose the inspection before choosing a filler
A crack at the corner of a bay may cross several materials or follow a previous repair. Describe its route and any changes noticed over time. Keep earlier photographs and information about replacement windows or other alterations available. If the condition raises a movement or stability concern, obtain the appropriate professional assessment before agreeing the surface treatment.
An inspection proposal should say what can be established visually and what needs closer examination. Ask for the findings to distinguish damaged finish, uncertain background and adjoining work by another trade. That gives the quotation a useful starting point. It also avoids treating several different defects around the same feature as one identical filling task.
Compare texture at the intended scale
A coarse finish is read as an area, not only as a handful of grains. Ask for a sample large enough to assess the intended texture and view it beside the retained work. On a curved surface, look from the approach to the house and from the side. A small smooth test in a sheltered corner will not show how the proposed repair reads around the bay.
Agree whether the adjacent coating is staying, being cleaned or receiving a compatible finish as part of the project. Each choice changes the comparison being made. Keep the accepted reference and the final decorative boundary with the quote. If extending the finish across a whole feature is offered, ask what extra preparation is required and which sound areas would be affected.
Protect the retained details during preparation
List the features beside the patch that must remain: glazing, window hardware, tile details, brick faces, paving and planting. Ask how they will be protected during removal and finishing, and identify any item that needs a different trade. If a window is being replaced, settle the order before either contractor finishes their edge.
Older finishes or adjacent components may require asbestos investigation before disturbance. Supply the available records and have any uninspected area considered within the proposed work. Dust-producing removal also needs suitable controls. For a ground-floor bay next to the main door, agree the safe route for people and when access has to change. Protection should be part of the programme from the first preparation stage.
Check the quotation against the marked feature
Compare proposals against the same drawing or photograph. Each should identify the initial repair, any allowance for unforeseen background work, the sample process and the final finish area. Ask how a changed extent will be priced and authorised. A lower initial figure can describe a narrower scope, particularly where curved returns and low-level details are omitted.
When work is complete, keep photographs of the repaired profile and any exposed background that affected the specification. Record the actual materials and agreed changes. Inspect the bay from the normal viewing positions, then check the less obvious edges at the base and beside the frame. This leaves a clear account of the work for later maintenance or a future window replacement.
Questions and answers
Does roughcast have to be removed across the whole bay?
The inspected condition and the agreed appearance determine the extent. Ask for local repair and wider finishing options to identify precisely what each would remove, retain and refinish.
Can the new render cover the brick base?
That is a change to the wall detail, not simply a patch repair. The existing construction, ground levels, moisture arrangements and any planning constraints need checking before an altered finish is specified.
Local context
Kirkside is described as roughcast-rendered above a brick plinth.
Kirkside, Hack Lane, Sutton in Ashfield Church and Market Place Conservation AreaEvidence period: March 2015 appraisal; Hack Lane entrySource checked: 22 November 2026Sutton Church and Market Place Conservation PlanThe appraisal records a curved ground-floor bay and tile-crease lintels at windows and doors.
Kirkside, Hack Lane, Sutton in Ashfield Church and Market Place Conservation AreaEvidence period: March 2015 appraisal; Hack Lane entrySource checked: 22 November 2026Sutton Church and Market Place Conservation PlanSources and further reading
- Sutton Church and Market Place Conservation PlanRelease/version: March 2015 appraisal; current official download uploaded 5 September 2025Source checked: 22 November 2026
- Approved Document C: resistance to contaminants and moistureApproved Document C: site preparation and resistance to contaminants and moisture, 2004 edition incorporating 2010 and 2013 amendments. Crown copyright 2013.Release/version: 2004 edition incorporating 2010 and 2013 amendments; August 2013 reprintSource checked: 22 November 2026
- Historic England: structural movementRelease/version: 29 August 2013Source checked: 22 November 2026
- HSE: arrange an asbestos surveyContains public sector information published by the Health and Safety Executive and licensed under the Open Government Licence v3.0.Release/version: Page last reviewed 1 March 2021Source checked: 22 November 2026
- HSE: chasing concrete and raking mortarContains public sector information published by the Health and Safety Executive and licensed under the Open Government Licence v3.0.Release/version: Page last reviewed 12 November 2024Source checked: 22 November 2026
- HSE: protecting the publicContains public sector information published by the Health and Safety Executive and licensed under the Open Government Licence v3.0.Release/version: Footer date 22 June 2026; checked 22 November 2026Source checked: 22 November 2026